Valid C_TAW12_750 Exam Q&A PDF C_TAW12_750 Dump is Ready (Updated 330 Questions) [Q158-Q174]

Share

Valid C_TAW12_750 Exam Q&A PDF C_TAW12_750 Dump is Ready (Updated 330 Questions)

Exam Questions and Answers for  C_TAW12_750 Study Guide

NEW QUESTION 158
What does Software Layer Aware Debugging allow you to do? Select all that apply.

  • A. Debug a large portion of code
  • B. Bypass authorization objects
  • C. Debug only a small portion of code
  • D. Specify as much or as little code to debug
  • E. Trace executing cod

Answer: A,C,D

 

NEW QUESTION 159
Which of the following Data Types are allowed in ABAP?
There are 2 correct answers to this question.
Response:

  • A. DECFLOAT32
  • B. DECFLOAT34
  • C. DECFLOAT64
  • D. DECFLOAT16

Answer: B,D

 

NEW QUESTION 160
Which database objects can you create in the ABAP Dictionary?
There are 2 correct answers to this question
Response:

  • A. Indexes
  • B. Foreign key relationships
  • C. Logical databases
  • D. Projection views

Answer: A,D

 

NEW QUESTION 161
What is the result of the following arithmetic operation?
DATA: int TYPE I.
int = 5*(3/10).{1 Richtig}

  • A. 0
  • B. D2
  • C. 1
  • D. 1.5

Answer: A

 

NEW QUESTION 162
Which of the following is a true statement?
There are 2 correct answers to this question.
Response:

  • A. An access key is required to enhance an SAP application using a user exit.
  • B. An access key is required to implement an implicit enhancement point.
  • C. An access key is required to implement business add-ins.
  • D. An access key is required to modify SAP repository objects.

Answer: A,D

 

NEW QUESTION 163
In an ABAP program you have the following code sequence :
DATA text TYPE string.
DATA Text_ref TYPE REF TO string.
DATA data_ref TYPE REF TO data.
FIELD-SYMBOLS <fs> TYPE any
Text = 'Content of Data Object'
GET REFERENCE OF text INTO data_ref.
Which of the following pieces of code can you use to output the content of variable text?
There are 2 correct answers to this question.
Response:

  • A. WRITE data_ref->*.
  • B. text_ref ?= data_ref.
    WRITE text_ref->*.
  • C. ASSIGN data_ref->* TO<fs>
    WRITE <fs>
  • D. GET REFERENCE OF data_ref->* INTO text_ref. WRITE text_ref->*.

Answer: B,C

 

NEW QUESTION 164
Setting breakpoints for a method or function module within the Debugger allows the use of (F4) (value help) to find the correct name.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 165
What can you do with the code inspector?
There are 2 correct answers to this question
Response:

  • A. Create your own inspections, object sets and check variants
  • B. Create an object set to represent the programs and objects to be inspected
  • C. Create only local inspections, objects sets and check variants
  • D. Choose from only the performance, security and user interface check categories

Answer: B,C

 

NEW QUESTION 166
An internal table can have primary keys as well as secondary keys.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 167
What is the result of the following arithmetic operation?
DATA: int TYPE I int = 5 /10 {1 Richtig}

  • A. 0
  • B. 1
  • C. 2

Answer: B

 

NEW QUESTION 168
What can be part of the signature of an instance constructor?
There are 2 correct answers to this question
Response:

  • A. Export parameters
  • B. Changing parameters
  • C. Exceptions
  • D. Import parameters

Answer: C,D

 

NEW QUESTION 169
How many work areas are available in the Debugger?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 170
For which of the following requirements can you implement a functional method? There are 2 correct answers to this question.

  • A. A private static helper method that returns a single value as the result of an algorithm
  • B. A method to set an instance attribute with one importing parameter and no other parameters
  • C. A handler method for an event that has a returning parameter
  • D. A factory method that returns an object reference

Answer: A,D

 

NEW QUESTION 171
Function modules provide which types of parameters? Select all that apply.

  • A. Output
  • B. Input
  • C. Return values
  • D. Exceptions
  • E. Input/output (changing)

Answer: A,B,D,E

 

NEW QUESTION 172
Which of the following items are used in a Web Dynpro Application to transport database data to the user interface?
There are 2 correct answers to this question.
Response:

  • A. Context node
  • B. Interface controller
  • C. Inbound plug
  • D. Supply function

Answer: A,B

 

NEW QUESTION 173
To generate the function modules for a lock object for a custom table (ENQUEUEJlock_object] and DEQUEUEJIock_object]), which tool would you use?

  • A. Reuse Library (Transaction SE83)
  • B. General Table Maintenance Dialog (Transaction SE54)
  • C. Text Elements (Transaction SE32)
  • D. Function Builder (Transaction SE37)
  • E. ABAP Dictionary (Transaction SE11)

Answer: E

 

NEW QUESTION 174
......

Certification dumps - SAP Certified Development Associate C_TAW12_750 guides - 100% valid: https://www.actualcollection.com/C_TAW12_750-exam-questions.html