NEW QUESTION # 57
When creating a new rule action, what is the best option to enable if too many events trigger the rule within a short time?
- A. flood protection
- B. entry count
- C. time window
- D. excessive event
Answer: A
NEW QUESTION # 58
How are additional collection ports added?
- A. separate listed ports with a comma in the NetFlowcollector services widget
- B. replace existingport with new port in theNetFlow collector services widget
- C. stop SolarWinds' NetFlow service and change the collection port in the NetFlow collector services widget
- D. stop SolarWinds' NetFlow service and separate listed ports with a comma in theNetFlow collector services widget
Answer: A
NEW QUESTION # 59
What is the unit of data used for alerting on flows?
- A. bPs
- B. gps
- C. mbps
- D. ms
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
The standard unit for flow-based alerts in SolarWinds (e.g., NetFlow Traffic Analyzer) is megabits per second (mbps). Alerts regarding traffic rates, bandwidth utilization, and similar flow metrics are configured and displayed in mbps for consistency with network monitoring best practices.
Reference:
"Traffic flow alert thresholds are set and displayed in megabits per second (mbps) within the SolarWinds web console and NTA."
- (Network Performance Monitor Administrator Guide, Alerting on Flow Traffic section)
NEW QUESTION # 60
Which two of the following locations can be checked for network hardware health functionality? (Choose two.)
- A. manage sensors
- B. device view
- C. node properties
- D. list resources
Answer: A,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
List Resources: When you add or manage a node, the List Resources page allows you to enable or verify hardware health monitoring options.
Manage Sensors: This section allows you to directly manage the hardware sensors (such as fans, power supplies, and temperature sensors) that report health status.
Device view and node properties are not the primary locations for enabling or managing hardware health sensors.
References:
NPM Administrator Guide: Hardware Health Monitoring and Sensor Management
NEW QUESTION # 61
What is the minimum amount of RAM required for setting up log collection in hybrid cloud observability?
- A. GB
- B. 32 GB
- C. 4 GB
- D. 16 GB
Answer: D
NEW QUESTION # 62
Flow data is not generating from a device in the web console. Wireshark was used to confirm the flows are being sent from the device to the poller and not blocked by the firewall. Why is the data not showing in the web console?
- A. device is not monitored by hybrid cloud observability (HCO) features
- B. flow monitoring was not enabled as device type in web console settings
- C. missing source address field in flow configurations
- D. device is using IPv6 and HCO only supports IPv4
Answer: C
Explanation:
If flows are confirmed as reaching the poller but no data appears in the web console, the most common cause is a missing or incorrect source address field in the flow configuration on the sending device. SolarWinds uses the source address to match incoming flows to the correct device record in its database; if this field is missing or misconfigured, the data will not be processed or displayed.
Exact Extract from Official Guide:
"If the source address field is missing or incorrectly configured in the flow-exporting device, the system cannot associate the flow with a monitored device, and no data will appear in the console."
- (Network Performance Monitor Administrator Guide, "Troubleshooting NetFlow" section) References:
Network Performance Monitor Administrator Guide, Troubleshooting NetFlow
NEW QUESTION # 63
Which two of the following tools are available for troubleshooting network node connectivity issues? (Choose two.)
- A. network insight
- B. NetPath
- C. MIB browser
- D. asset inventory
Answer: B,C
NEW QUESTION # 64
In which scenario would the device studio poller tool be considered the best tool for building a required poller?
- A. Building a poller to add missing information to node details.
- B. Building a poller for ARP tables to display in the web console.
- C. Building a poller to show CPU and memory status.
- D. Building a poller to monitor VPN tunnel status.
Answer: A
NEW QUESTION # 65
Which two of the following actions are recommended for more precise forecasting of capacity trends on critical devices? (Choose two.)
- A. Set calculation methods to use average daily values.
- B. More historical data used in calculations.
- C. Monitor devices with platform agents.
- D. Set warning and critical thresholds to lower percentages.
Answer: A,B
NEW QUESTION # 66
A "no data" message is displayed in NetFlow charts. How can this be resolved?
- A. Confirm account has viewing permissions.
- B. Refresh the current window.
- C. Restart collector service.
- D. Shorten the time for view and resource.
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
A "no data" message in NetFlow charts usually indicates that the flow collector service is not receiving or processing flow data. One of the primary troubleshooting steps recommended in the SolarWinds documentation is to restart the collector service. This resolves issues caused by service interruptions, memory leaks, or flow processing errors.
The documentation states:
"If NetFlow charts display 'no data,' verify that the NetFlow collector service is running. Restart the collector service if necessary, as service interruptions can cause a lack of flow data display." References:
Network Performance Monitor Administrator Guide, "Troubleshooting NetFlow No Data Issues" SolarWinds Success Center: "NetFlow Collector Service Troubleshooting"
NEW QUESTION # 67
Which two of the following reasons should NetFlow data be collected on a company network? (Choose two.)
- A. report network link up / down instances
- B. authorize user network access
- C. diagnose slow network performance
- D. identify applications causing congestion
Answer: C,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
B). NetFlow data is commonly used to diagnose network performance issues, such as identifying sources of congestion or bottlenecks.
C). NetFlow analysis provides visibility into which applications and endpoints are consuming bandwidth and causing congestion.
User authorization and link status events are not functions of NetFlow; those are handled by other monitoring tools or features.
References:
NTA Administrator Guide: NetFlow Use Cases and Benefits
NEW QUESTION # 68
What is the correct sequence of steps to create a device studio poller?
- A. Assign the poller to node, select the technology, specify the data source, and savethe poller.
- B. Select the technology, assign the poller to node, specify the data source, and save the poller.
- C. Select the technology, specify the data source, assign the poller to node, and save the poller.
- D. Select the technology, specify the data source, save the poller, and assign the poller to node.
Answer: D
NEW QUESTION # 69
The fan of a network device has failed; however, the status shows as "up" on the current hardware health resource in the node details view. Which two of the following causes could be creating the issue? (Choose two.)
- A. threshold of the fan sensor has been forced
- B. hardware sensors are disabled
- C. wrong MIB being used for polling
- D. resource is showing outdated information
Answer: C,D
NEW QUESTION # 70
Which two of the following reasons explain why device MIB files are important for SNMP polling in hybrid cloud observability? (Choose two.)
- A. MIB files contain all metrics available for pollingon the device.
- B. MIB files enable SolarWinds to create object IDs (OlDs) for customers to monitor.
- C. MIB files enable automatic discover/ of devices added to hybrid cloud
- D. MIB files enable hybrid cloud observability to display the metric in a user-friendly format.
Answer: A,C
NEW QUESTION # 71
What network capacity planning method is suitable for important devices and connections?
- A. peak calculation
- B. forecast calculation
- C. average calculation
- D. default calculation
Answer: A
NEW QUESTION # 72
Which tool can be used to display the physical layout of interfaces on graphical stencils?
- A. network insight
- B. device view
- C. NetPath
- D. device studio
Answer: B
Explanation:
The "Device View" feature allows users to view the physical layout of device interfaces on graphical stencils, providing an intuitive graphical representation of port locations and status.
Exact Extract from Official Guide:
"Device View displays the physical layout of device interfaces using graphical stencils for supported devices."
- (Network Performance Monitor Administrator Guide, "Device View" section) References:
Network Performance Monitor Administrator Guide, Device View
NEW QUESTION # 73
A "no data" message is displayed in NetFlow charts. How can this be resolved?
- A. Restart collector service.
- B. Refresh the current window.
- C. Confirm account has viewing permissions.
- D. Shorten the time for view and resource.
Answer: C
NEW QUESTION # 74
Which two of the following reasons should NetFlow data be collected on a company network? (Choose two.)
- A. report network link up / down instances
- B. authorize user network access
- C. diagnose slow network performance
- D. identity applications causing congestion
Answer: C,D
NEW QUESTION # 75
Which two of the following actions can be taken to resolve duplicate flows? (Choose two.)
- A. Ensure NetFlow export is enabled on sub-interfaces.
- B. Ensure NetFlow is enabled for ingress interfaces.
- C. Enable automatic addition of flow sources.
- D. Enable the flow de-duplication feature.
Answer: B,D
NEW QUESTION # 76
What can be done to display the average CPU utilization of a node in a web console widget, if the device studio poller returns a table of multi-core CPU utilizations?
- A. Display the returned table of values in the web console widget and manually calculate the average.
- B. Select the add calculated value option and use the average function for returned values.
- C. Configure the web console widget to calculate the average of the returned table values.
- D. Contact the device vendor to provide an SNMP object ID (OID)forthe averaqe CPU utilization statistic.
Answer: B
NEW QUESTION # 77
Several resources are showing duplicate flow data. What is the most likely cause?
- A. interfaces have duplicate entries in flow sources management
- B. SolarWinds' NetFlow service needs to be restarted
- C. interfaces in flow sources management are set to drop
- D. source devices are configured to export flow data on ingress and egress
Answer: D
NEW QUESTION # 78
A poller is to be built that will add two values together to show a single value in the web console using the universal device poller (UDP) tool. How would this be accomplished?
- A. build a poller for each OID then use transform results to combine values from the two pollers
- B. UDP tool does not support more than one OID per poller, another OID is needed
- C. add both object IDs (OIDs) to the poller and combine values in a single value for the web console
- D. UDP tool does not support more than one OID per poller, another tool is needed
Answer: A
NEW QUESTION # 79
A custom application is to be monitored in hybrid cloud observability's flow monitoring features. How is this application added for monitoring?
- A. Custom application ports cannot be added they may only be edited.
- B. Add the source or destination machine, then map it to application ports.
- C. Ensure the application is using IPv6 then map it to a source.
- D. Add the application ports, then assign it to a machine.
Answer: B
NEW QUESTION # 80
If an IP address group is hidden in IP address groups management, what impact will it have on the data?
- A. group will be shown in compliance reports
- B. group will not be shown in IPAM
- C. group will not be shown in charts or reports
- D. group historical data will be deleted
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Hiding an IP address group in IPAM management means that group will not appear in dashboards, charts, or reports, but the underlying data and group definition remain intact and are not deleted.
Reference:
"When an IP address group is hidden, it will not appear in IPAM charts or reports, but historical data is retained unless deleted."
- (IP Address Manager Administrator Guide, IP Address Group Management section)
NEW QUESTION # 81
......
Get Instant Access REAL Hybrid-Cloud-Observability-Network-Monitoring DUMP Pass Your Exam Easily: https://www.actualcollection.com/Hybrid-Cloud-Observability-Network-Monitoring-exam-questions.html