HP HPE0-S59 (HPE Compute Solutions) Certification Exam is a highly sought-after certification program that validates the skills and expertise of IT professionals in designing and implementing HPE compute solutions. HPE0-S59 exam is designed to test the technical knowledge and skills required to design, deploy, and manage HPE compute solutions in complex enterprise environments. HPE Compute Solutions certification is ideal for IT professionals who want to enhance their career prospects and take their skills to the next level.


HPE0-S59 exam is a comprehensive test that requires a thorough understanding of HPE compute solutions. It is a challenging exam that requires the candidate to have hands-on experience with HPE solutions. HPE0-S59 exam consists of multiple-choice questions, and the candidate has two hours to complete it. The passing score for the exam is 65%, and the certification is valid for three years.

 

NEW QUESTION # 60
Which statement about the HPE D3940 storage module is true?

  • A. Only one type of drives (SATA, SAS, SSD) can be installed in each module
  • B. SATA drives requires redundant 10 adapters to be installed in this module
  • C. Up to five modules can be installed in a single frame with Gen10 servers
  • D. it is configured through CLl available from HPE Synergy console

Answer: D


NEW QUESTION # 61
Which statement about HPE Superdome Flex 280 is true?

  • A. It must be equipped with at least 768 GB of memory.
  • B. it cannot be managed using HPE OneView.
  • C. It can support up to two nPars with an external RMC.
  • D. It supports 2 to 8 sockets in 2-socket increments.

Answer: D


NEW QUESTION # 62
Which statement about a new HPE SimpliVity deployment is true?

  • A. All new HPE SimpliVity models are based on mid CPUs
  • B. New HPE SimpliVity deployments gives customer flexible choice of hypervisor
  • C. AM new HPE SimpliVity models are software optimized
  • D. A new HPE SimpliVity node can be a member of multiple dusters

Answer: B

Explanation:
New HPE SimpliVity deployments offer customers the flexibility to choose between different hypervisors, such as VMware vSphere and Microsoft Hyper-V. This flexibility allows customers to select the hypervisor that best fits their existing infrastructure and operational preferences.


NEW QUESTION # 63
Your customer plans to add four HPE Synergy frames to an existing management ring Ail installed frames are equipped with two 2-port FLM modules, while new frames will be equipped with 4-port FLM modules.
Which statement about mixing different FLM modules is true?

  • A. Mixing different FLM modules is allowed if all of them have the same firmware version
  • B. Existing 2-port FLM modules must be replaced with 4-port FLM modules
  • C. A management ring can contain mixed frame link module configurations
  • D. A management ring with mixed FLM modules cannot have more than 12 frames

Answer: D


NEW QUESTION # 64
Your customer plans to deploy VMware ESXi 7.0 U2, and they are looking for a hardware platform that will allow them to use up to 24 TB of physical memory.
Which HPE compute system meets the customer's requirements?

  • A. HPE Synergy 480 Gen10 Plus
  • B. HPE Superdome Flex
  • C. HPE ProLiant DL380 Gen 10 Plus
  • D. HPE ProLiant DL580 Gen 10

Answer: B


NEW QUESTION # 65
You discovered that somebody deleted the SSO certificate that affects accessing iLO from HPE OneView from an iLO processor in an HPE Synergy compute node.
How will you recover from this problem?

  • A. Remove the affected server from HPE OneView and add it again to reconfigure the iLO processor.
  • B. Login to the HPE Composer CLI and use the efuse procedure for the affected server.
  • C. Navigate to HPE OneView, locate the affected server hardware and use Refresh option.
  • D. Navigate to HPE OneView, locate the affected server hardware and use the Reset iLO option.

Answer: C


NEW QUESTION # 66
An HPE Synergy customer needs to prevent a timeout and loss of communication during an external switch firmware upgrade.
Click the parameter that the customer should configure within an uplink set to meet this requirement

Answer:

Explanation:

Explanation:
To prevent a timeout and loss of communication during an external switch firmware upgrade, the customer should configure theLACP failover triggerwithin the uplink set. By setting the LACP failover trigger to "All active uplinks transition to offline," the configuration ensures that the traffic will be redirected to available uplinks in the event of an uplink failure or during the upgrade process, maintaining communication and preventing timeouts.


NEW QUESTION # 67
Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.

Answer:

Explanation:

Explanation:
TheLifecycle Managerin the vSphere Client interface is used for managing and updating ESXi hosts, including changing the ESXi image used in an OS Deployment Plan. This tool allows administrators to import, export, and apply different ESXi images, ensuring that the hosts are running the desired version and configuration of ESXi.


NEW QUESTION # 68
Your customer needs to move an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen 10 Compute Module. The 480 has a switch that has been manually zoned outside of HPE OneView.
What must the customer do before migrating the application?

  • A. Create a new server profile template and apply to the new hardware
  • B. Edit the server profile and change server hardware type
  • C. Migrate the application to a Logical JBOD and connect it to the new server
  • D. Copy the server profile and assign the clone to the new hardware

Answer: D

Explanation:
When migrating an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen10 Compute Module, the recommended approach is to copy the server profile and assign the clone to the new hardware. This ensures that all the necessary configuration settings, including network and storage configurations, are retained and applied to the new compute module. Since the switch zoning is manually configured outside of HPE OneView, copying the server profile helps in maintaining consistency in the network settings during the migration.


NEW QUESTION # 69
Click the drop-down menu that will allow you to define the location of the master modules within the logical interconnect group.

Answer:

Explanation:


NEW QUESTION # 70
Your customer plans to expand an existing nPar based on a single HPE Superdome Flex chassis. Which statement about workload availability during expansion is true?

  • A. Online expansion is available only if RMC is used for management.
  • B. Powered nPar can be expanded only if HPE Superdome Flex 280 is used
  • C. Powered nPar can be expanded if it does not use HPE Persistent Memory
  • D. HPE Superdome Flex does not support expansion of powered on nPars

Answer: C

Explanation:
HPE Superdome Flex allows for the expansion of powered-on nPars (nPartitions), but this capability is subject to certain conditions. One of these conditions is that the nPar does not use HPE Persistent Memory.
Expanding an nPar with Persistent Memory typically requires a shutdown to reconfigure the memory settings safely.


NEW QUESTION # 71
Your customer plans to deploy HPE OneView for VMware vCenter Server together with HPE Storage Integration Pack for VMware vCenter.
The customer wants to use them to manage HPE Synergy Gen10 compute modules, HPE ProLiant Gen10 servers, and an MSA array.
Which statement about compatibility of the existing environment with the planned software components is true?

  • A. HPE OneView for VMware vCenter Server does not support standalone HPE ProLiant servers.
  • B. Both HPE Synergy Gen10 full-height compute modules plugins will require a license.
  • C. Not all of HPE Storage Integration Pack for VMware vCenter features are supported with MSA arrays.
  • D. HPE ProLiant Gen10 systems require HPE OneView for VMware vCenter server licenses for each node.

Answer: C


NEW QUESTION # 72
Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.

Answer:

Explanation:


NEW QUESTION # 73
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They plan to use Distributed Switches and DRS cluster You are preparing a proposal with the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- an appropriate number of the vSphere Standard licenses for each compute node
- one HPE D3940 Storage Modules with 40 SSDs - all required cables and options Which statement about this proposal is true?

  • A. vSphere Standard licenses should be replaced with Enterprise Pius licenses to enable requested features
  • B. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM
  • C. 2 additional HPE Synergy 480 Gen10 Plus compute modules can be added to this setup
  • D. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drive.

Answer: A

Explanation:
The VMware vSphere Standard license does not include support for advanced features like Distributed Resource Scheduler (DRS) and Distributed Switches. These features are available onlywith the vSphere Enterprise Plus license. Therefore, to meet the customer's requirement of using Distributed Switches and a DRS cluster, the proposal should include vSphere Enterprise Plus licenses instead of Standard licenses.


NEW QUESTION # 74
After deploying HPE Superdome Flex 280 you need to check Core Analysis Engine (CAE) Log.
Click the appropriate section in the HPE Superdome Flex 280 management interface that will allow you to complete this task.

Answer:

Explanation:


NEW QUESTION # 75
Your customer has an HPE Synergy platform deployed and managed using HPE OneView. The customer also has HPE Superdome Flex with RMC deployed They plan to deploy a second nPar and HPE Superdome Flex
280 They plan to manage new components using HPE OneView
What must be done to achieve this goal?

  • A. The customer must use IL05 to add HPE Superdome Flex systems to HPE OneView
  • B. The customer should deploy an HPE OneView appliance for HPE Superdome Flex management
  • C. The customer has to add HPE Superdome Flex to the HPE OneView used to manage HPE Synergy
  • D. The customer must add a second Rack Management Controller for HPE Superdome Flex 280

Answer: C

Explanation:
To manage HPE Superdome Flex systems, including the new Superdome Flex 280, using HPE OneView, the customer should deploy a dedicated HPE OneView appliance specifically for HPE Superdome Flex management. This approach ensures that the Superdome Flex systems are properly integrated and managed within the HPE OneView environment, allowing for consistent and centralized management alongside other HPE infrastructure.


NEW QUESTION # 76
Which compute node parameters are captured within server hardware type?

  • A. Mezzanine card configuration
  • B. Size of the memory Installed
  • C. installed operating system
  • D. Number of the CPUs

Answer: C


NEW QUESTION # 77
What is a restriction of using a RoCE network?

  • A. It does not support smart link and private network features.
  • B. it is not supported with HPE Virtual Connect SE 40 GD F8 Module for HPE Synergy.
  • C. It does not support Private VLAN and Multicast VLAN.
  • D. It is by default configured as an untagged network and cannot be a part of a network set.

Answer: A

Explanation:
A restriction of using a RoCE (RDMA over Converged Ethernet) network is that it does not support smart link and private network features. These features are essential for certain network configurations and use cases, but they are not available in RoCE networks, which are designed for high-performance, low-latency communication.


NEW QUESTION # 78
Your customer plans to deploy HPE Superdome Flex and configure two nPars, each based on two chassis Which components must be included in the proposal to meet the customer's needs?

  • A. Rack Management Controller for nPar management
  • B. At least Tour HPE Persistent Memory DIMMs per nPar
  • C. One base chassis and three expansion chassis with licenses
  • D. HPE Superdome Flex Grid licenses enabling connectivity between chassis

Answer: D

Explanation:
To deploy HPE Superdome Flex and configure two nPars, each based on two chassis, you must include the HPE Superdome Flex Grid licenses. These licenses enable connectivity between the chassis, allowing the creation of nPars (nPartitions) that span multiple chassis. This is essential for the system's proper configuration and operation in a multi-chassis nPar setup.


NEW QUESTION # 79
Click the port on the Frame Link Module which is used to include an HPE Synergy frame in the management ring.

Answer:

Explanation:

Explanation:
The port labeled "MGMT" (Management) in the upper right section of the HPE Frame Link Module (FLM) is the correct port used to include an HPE Synergy frame in the management ring. This port is crucial for linking the frame into the management network of the Synergy infrastructure.


NEW QUESTION # 80
Which statement about an HPE Oneview support dump is true?

  • A. Support dump can be created if HPE Virtual Connect modules are installed in the frame
  • B. Preview support dump is available only when creating an appliance support dump
  • C. Appliance support dump by default contains a logical enclosure support dump
  • D. Support dump is a binary file that can be opened only in a dedicated application

Answer: D


NEW QUESTION # 81
......

Pass Your Next HPE0-S59 Certification Exam Easily & Hassle Free: https://www.actualcollection.com/HPE0-S59-exam-questions.html

Get Prepared for Your HPE0-S59 Exam With Actual HP Study Guide!: https://drive.google.com/open?id=17o_vQ16XMgAwaQVt_TpB8XkggcUGWd0s